Shop

All-In-One SPE Platform (2xAdd-ons)

AIO-SPE cell with two add-ons for using printed electrodes in static and dynamic conditions. The cell includes the Flow and Batch add-ons. The cell is also compatible with EEP platform

All-In-One SPE Platform (2xAdd-ons)

Material: Aluminium base + methacrylate add-ons

Dimensions: 60 x 40 x 15/30 mm (W x D x H)

Contents: AIO cell + 2 Add-ons (Flow and Batch) + SPE cable (male or female banana end)

Details: Easy and fast electrode replacement. Easy add-ons assembly (tool free). Reusable - long life

ED-AIO-SPE-CELL-2x

AIO-SPE

All-In-One SPE Platform (1xAdd-on)

AIO-SPE cell with one add-on for using printed electrodes in static or dynamic conditions. Compatible with Flow or Batch add-ons. The cell is also compatible with EEP platform.

All-In-One SPE Platform (1xAdd-on)

Material: Aluminium base + methacrylate add-ons

Dimensions: 60 x 40 x 15/30 mm (W x D x H)

Contents: AIO cell + 1 Add-on (to be chosen) + SPE cable (male or female banana end)

Details: Easy and fast electrode replacement. Different movable add-ons are available. Easy add-ons assembly (tool free). Reusable - long life

ED-AIO-SPE-CELL-1x

Printed Carbon Single Electrode

Thick-film Carbon Electrode

Carbon-based screen-printed electrodes with a classical three-electrodes approach. Ideal to work with microvolume, showing an excellent intra- and inter-electrode precision. Useful for developing low-cost, disposable chemical sensors and biosensors. Different accessories available.

Thick-film Carbon Electrode

Dimensions: 27.5 x 10.1 x 0.35 mm

Substrate: PET (white)

Electrodes material: WE: C / RE: Ag / AE: C

WE size: 3 mm Ø (7.1 mm2)

Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors

Contents: 50 units/box

ED-S1PE-C (50 units/box)

IDE connector

CABLE connector for thin-film IDE electrodes

IDE-CABLE connector provides an interface between the thin-film IDµElectrodes (IDE - two contact pads) and the potentiostat, enabling the use of microvolume (2 – 10 µL sample drops) or dipping into a solution.

CABLE connector for thin-film IDE electrodes

Dimensions: 50 cm long

Contents: 1 x IDE cable (with 2-mm male or female ends to be selected)

Controller: Accessory for thin-film InterDigitated Electrodes (IDE)

ED-IDE-CABLE

BOX connector

BOX connector for thick-film electrodes

SPE-BOX connector provides an interface between the screen-printed electrodes and any kind of potentiostat, enabling the use of microvolume (20 – 50 μL sample drops).

BOX connector for thick-film electrodes

Dimensions: 58 x 40 x 15 mm (L x W x H)

Contents: 1 x BOX interface (with 2-mm female terminals)

Details: Accessory for thick-film electrodes

ED-SPE-BOX

CABLE connector

CABLE connector for thick-film electrodes

SPE-CABLE connector provides an interface between the printed electrodes and the potentiostat, enabling the use of microvolume (20 – 50 μL sample drops) or dipping into a solution.

CABLE connector for thick-film electrodes

Dimensions: 50 cm long

Contents: 1 x SPE cable (with 2-mm male or female ends to be selected)

Details: Accessory for thick-film electrodes

ED-SPE-CABLE

MicruX ECStat

ECStat Electrochemical Station

USB-powered All-in-One Electrochemical Workstation, including a Bipotentiostat / Galvonostat with built-in Impedance Analyzer, in a very compact and portable equipment. USB interfacing and fully controlled by MicruX EC Manager PC software. More than 25 electroanalytical techniques. Compatible with electrochemical platforms and electrochemical sensors.

ECStat Electrochemical Station

Dimensions: 160 x 100 x 45 mm (L x W x H)

Operating modes: bipotentiostat, potentiostat, ZRA, galvanostat, PEIS analyzer

LED indicators: power on, cell on

Comm. interface: USB-C

Power supply: USB

Operating temperature: 0 ºC to +50 ºC

DC-potential range: ± 10 V

Compliance voltage: ± 10 V

DC-potential resolution: 75 µV

Applied potential accuracy: ≤ 0.1% ± 1 mV offset

Current ranges: 100 pA to 10 mA (9 ranges)

Maximun DC current: ± 30 mA

Current accuracy: ≤ 0.1 % (at Full Scale Range)

Measured current resolution: 0.006 % of current range (5 fA on 100 pA range)

EIS - Frequency range: 10 μHz to 1 MHz

EIS - AC-amplitude range: 1 mV to 250 mV rms, or 0.6 V p-p

Housing: Aluminum case

Weight: < 0.5 Kg

Certificates: CE

Details: MicruX ECStat is provided in a plastic briefcase with all the accessories and software for interfacing with the computer and sensors.

ECSTAT

MicruX ECStat

ECStat Electrochemical Station

USB-powered All-in-One Electrochemical Workstation, including a Bipotentiostat / Galvonostat with built-in Impedance Analyzer, in a very compact and portable equipment. USB interfacing and fully controlled by MicruX EC Manager PC software. More than 25 electroanalytical techniques. Compatible with electrochemical platforms and electrochemical sensors.

ECStat Electrochemical Station

Dimensions: 160 x 100 x 45 mm (L x W x H)

Operating modes: bipotentiostat, potentiostat, ZRA, galvanostat, PEIS analyzer

LED indicators: power on, cell on

Comm. interface: USB-C

Power supply: USB

Operating temperature: 0 ºC to +50 ºC

DC-potential range: ± 10 V

Compliance voltage: ± 10 V

DC-potential resolution: 75 µV

Applied potential accuracy: ≤ 0.1% ± 1 mV offset

Current ranges: 100 pA to 10 mA (9 ranges)

Maximun DC current: ± 30 mA

Current accuracy: ≤ 0.1 % (at Full Scale Range)

Measured current resolution: 0.006 % of current range (5 fA on 100 pA range)

EIS - Frequency range: 10 μHz to 1 MHz

EIS - AC-amplitude range: 1 mV to 250 mV rms, or 0.6 V p-p

Housing: Aluminum case

Weight: < 0.5 Kg

Certificates: CE

Details: MicruX ECStat is provided in a plastic briefcase with all the accessories and software for interfacing with the computer and sensors.

ECSTAT

Bipotentiostat USB-Cable

Bipotentiostat USB-Cable

Bipotentiostat cable with miniUSB plug for using in combination with MicruX® ECStat to directly connect the MicruX’ electrochemical platforms with thin-film electrodes.

Bipotentiostat USB-Cable

Dimensions: 50 cm long

Contents: 1 x Bipot cable (miniUSB end)

Details: Accessory for MicruX® ECStat electrochemical workstation and MicruX' electrochemical platforms

ECSTAT-USB

Bipotentiostat cable

Bipotentiostat Cable

Bipotentiostat cable with 2-mm male banana plug (+ alligator clips) for using in combination with MicruX® ECStat to connect the electrodes of detection system.

Bipotentiostat Cable

Dimensions: 100 cm long

Contents: 1 x Bipot cable (male end) + 4 x alligator clips

Details: Accessory for MicruX® ECStat electrochemical workstation

ECSTAT-CAB2M

LSP02-2B Dual-channel Syringe Pump

LSP02-2B Dual-channel Syringe Pump

2-channels syringe pump with infusion/ withdrawal mode. The acceptable syringe specification is from 10 µL to 140 mL. Suitable for high accuracy and small flow rate liquid transferring. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP02-2B Dual-channel Syringe Pump

Dimensions: 280 x 250 x 140 mm (D x W x H)

Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous

Channels: 2

Advance per step: 0.156 µm

Linear force: > 180 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.83 nL/min – 150.5 mL/min

Syringe size: 10 µL – 140 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 130 mm/min

Min. linear rate: 5 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 20W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 4.3 Kg

Certificates: CE, EMC, ESD ≥ Level IV (IEC 61000-4-2)

LSP02-2B

LSP01-1A Single-channel Syringe Pump

LSP01-3A Single-channel Syringe Pump

Just infusion single-channel syringe pump with 5 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP01-3A Single-channel Syringe Pump

Dimensions: 280 x 210 x 140 mm (D x W x H)

Working mode: Infusion

Channels: 1

Advance per step: 0.156 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.83 nL/min – 54.2 mL/min

Syringe size: 10 µL – 60 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 65 mm/min

Min. linear rate: 5 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 15W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 3.6 Kg

Certificates: CE, EMC, ESD ≥ Level IV (IEC 61000-4-2)

LSP01-3A

91 Products. View all

Returns

All the information that you should know about our returns policy...

More information

Contact

Contact us to solve your doubts or answer your questions. We can help you!

More information

Delivery

We ship the products under strict security measures, ensuring their protection...

More information

subscribe to our monthly newsletter